Michelson Interferometer

Interferogram → spectrum via Fourier transform. Core of FTIR spectroscopy.

Model: Exact

Resolution δσ = 1/L

100 cm⁻¹

0.01 µm⁻¹; Δλ = λ²/L = 10 nm

Resolving Power L/λ

100

ILS FWHM 60.34 cm⁻¹ (Boxcar (none))

Nyquist Wavenumber

25600 cm⁻¹

step 0.1953 µm; λ_min = 0.3906 µm

Fringe Visibility ½ at

220.6 µm

OPD where a line's fringes fade to half

Interferogram

-202020406080OPD x (µm)I(x)
  • I(x)

Recovered spectrum

00.51.09.0k9.5k10.0k10.5k11.0kWavenumber σ (cm⁻¹)B(σ) (normalized)
  • Recovered B(σ)

Two-beam fringes at the central wavelength

Optical Path Difference

20 µm

2ΔL (light crosses each arm twice)

Fringe Order OPD/λ

20

phase 0° past a bright fringe

Detector: Visibility V

0.9943

I = 0.8974 of the input; beams 0.225 and 0.225

Coherence Factor |γ|

0.9943

Gaussian line of the FWHM above, at this OPD

Model

I(x) = Σ cos(2πσᵢx)·exp(−(πΓx)²/(4 ln 2))·A(x/L), B(σ) = Δx[I₀ + 2Σ Iₙ cos(2πσnΔx)]

δσ = 1/L, σ_Nyquist = 1/(2Δx), Δx = L/N

Each Gaussian line of FWHM Γ (cm⁻¹) contributes a cosine fringe whose envelope is the Fourier transform of its profile, so broad lines lose fringe contrast within a short OPD. The single-sided interferogram, sampled at N points from zero path difference to L, is cosine-transformed (FFT of the mirrored record, zero-padded for a smooth curve) to recover the spectrum, convolved with the instrument line shape of the chosen apodization. Lines closer than about 1/L merge; lines above the Nyquist wavenumber fold back. The interferometer is ideal: no beam divergence, phase error or detector response. The Fellgett (multiplex) advantage comes from measuring all wavenumbers in every sample.

I = I₁ + I₂ + 2√(I₁I₂)|γ| cos(2π·OPD/λ), V = 2√(I₁I₂)|γ|/(I₁ + I₂)

Two-beam fringes use lossless splitters. In the Michelson both beams meet the splitter once in reflection and once in transmission (I₁ = R T R₁, I₂ = T R R₂), so the splitter ratio sets the throughput but not the visibility. In the Mach-Zehnder output A receives Rₐ T_b and Tₐ R_b and output B receives Rₐ R_b and Tₐ T_b, with complementary fringes that sum to the input. |γ| is the coherence of one Gaussian line of the FWHM set above.

Model and references

Exact. The equations are exact within the stated assumptions, or are a standard's tabulated values. The results are as good as the inputs. About the tiers

Ideal two-beam interferometer with Gaussian lines, sampled single-sided from zero path difference; no beam divergence, phase error or detector response. Fringes: lossless splitters and plane waves, visibility from the beam powers and the line's coherence.

  1. Griffiths P. R., de Haseth J. A. (2007). Fourier Transform Infrared Spectrometry, 2nd ed., chs. 2 and 4. Wiley.
  2. Born M., Wolf E. (1999). Principles of Optics, 7th ed., ch. 7 (two-beam interference) and ch. 10 (partial coherence). Cambridge University Press. doi:10.1017/CBO9781139644181
  3. Hariharan P. (2003). Optical Interferometry, 2nd ed., ch. 2. Academic Press.