Penetration Depth Calculator

Optical penetration depth from the complex index n + ik at any angle of incidence: d_p = λ₀/(4π Im √(N² − n₀² sin²θ)), covering absorbing media, metals (skin depth) and total internal reflection.

Model: Exact

Absorption Coefficient α

157.1 cm⁻¹

4πk/λ₀ = 1.571e+4 m⁻¹

Intensity Depth d_p at θ

63.66 µm

1/e of intensity, normal to the surface; refracted wave, absorbed

Field 1/e Depth 2d_p

127.3 µm

skin depth λ₀/(2πk) at normal incidence

Depth at Normal Incidence 1/α

63.66 µm

λ in medium λ₀/n = 533.3 nm

Normal incidence: α = 4πk/λ₀, intensity I(z) = I₀ e^(−αz), d_p = 1/α.

Oblique incidence from index n₀: k_z = (2π/λ₀) √(N² − n₀² sin²θ), N = n + ik, so d_p = λ₀ / (4π · Im √(N² − n₀² sin²θ)).

This one formula gives 1/α at normal incidence and the evanescent TIR depth for k = 0 above the critical angle. The intensity is the depth-dependent factor of the transmitted field; reflection losses at the surface are not included.

Model and references

Exact. The equations are exact within the stated assumptions, or are a standard's tabulated values. The results are as good as the inputs. About the tiers

Exact plane-wave result for one planar interface from a lossless medium: the depth is that of the transmitted (or evanescent) field; reflection at the surface is not included.

  1. Born M., Wolf E. (1999). Principles of Optics, 7th ed., ch. 14 (optics of metals). Cambridge University Press.
  2. Axelrod D. (2001). Total internal reflection fluorescence microscopy in cell biology. Traffic 2, 764–774 (eq. 2). doi:10.1034/j.1600-0854.2001.21104.x